Empanelled with PGCIL GOI Accredited Star Export house In House NABL Accredited Test Lab BIS Certified Transformers upto 2500 KVA/33 KVA class ISO 9001: 2008 ISO 14001: 2004 OHSAS 18001: 2007

mark

TRANSFORMER DIVISION

AREA OF EXPERTISE

In an effort to provide the benefit of the state-of-art technology to our valued customers, the PME team of professional of technocrats are engaged in continuous R&D an innovative designs in the line with highest standards of quality assurance .The transformers are designed to meet the values of No Load, Load Loss & Expected stray loss , temperature rise, winding hot spot, and noise level. Great emphasis is put on using the right value for critical parameters like flux density, current density, loss dissipation factor etc. Our current production capacity is of over 24,000 transformers of assorted rating from 10KVA/11 Kv class to 150 MVA/330 KV class.

Our transformer tanks are given shot blasting treatment followed by hot zinc spray treatment by flame gun and trouble free services in all sorts of climatic process to give a long lasting, corrosion conditions prevailing at the site. Ultra violet x-ray machine with fluorescent die-penetrating equipment is used to identify the welding cracks on the tank joints. This is followed by air pressure and vacuum test of tank body, measurement of paint coating thickness and leakage test on complete transformer to ensure leak free transformers.

The in-house QC Lab tests every product as per IEC-60076/ BS / IS-2026. Each and every component used in transformer undergoes series of stringent checks and controls at each stage of manufacture. It is ensured that strict technical and qualitative specifications are adhered to meticulously and religiously. Some of the tests carried out are: Measurement of winding resistances, voltage ratio, phase displacement, short-circuit impedance and load loss, no-load loss and no-load current. These are followed by a series of Di-Electric Tests like separate source power frequency test on both primary and secondary sides, induced over voltage test, break down value, resistivity and tan-delta dissipation factor of transformer oil, insulation resistance measurement test, temperature rise test and measurement of noise levels. Mechanical test like air pressure and vacuum test of tank body, measurement of paint coating thickness, Leakage test on complete transformers. Besides in-house test, transformers are tested for dynamic/thermal tests at CPRI.

MANUFACTURING CAPABILITIES

For Power Transformer:Core type 3 phase, Generator Transformer, Unit Auxiliary Transformers, Step up and step down Transformers, Interconnecting. Auto Transformers, Dual Voltage Primary or Secondary Three winding Transformers

For Distribution Transformer:Core type single phase, Three winding Transformers, Step up and step down Transformers, Dual Voltage Primary or Secondary

For Special Transformer: Induction Furnace & Arc Furnace Transformers,Rectifier transformers,Auto transformers Voltage Regulators,Earthing Transformer, Booster, Servo Stabilizers,Isolation ,Thyristor Duty Transformers,Invertors & Converter Transformers,Mining Transformers,Railway Signaling Transformers,Testing High Voltage & Intermediate Transformers,Current Injection Transformers,Transformers for AC & DC Drives etc.

All requisite facilities for core building upto 70 tonnes,Winding machine upto 10 Tonne capacity.Lifting Capacity upto 150 Metric Tonne .Vacuum Drying oven,Motor generator Set for testing.No load /Load loss impedance test of transformer.the HV Testing potential dividers,Power Analyzers ,Tan Delta and capacitance testing.
The Impulse Test/Short Circuit Test are organized with 3rd parties at CPRI/eq. Lab.

PRODUCT RANGE

Our Company is primarily engaged in the business of manufacturing of oil filled transformers of up to 150 MVA/330 KV class.
Our current range of products and their applications can be summarised as follows:


POWER TRANSFORMERS

The design comprises of electrical, mechanical & thermal parameters base on customer specification ISO 9001/IEC Standard/BS/IS Standards.
The core is 3 Phase ,Three limb, Five limb or seven limbs, Core duct is provided to limit core Hot Spot.
HI-B/laser inscribed sheet steel is choosen as per requirement. Boltless Core is adopted to avoid Hot Spots in Core legs.
The Interleaved/Intershield Disc/Helical Coils are adopted.

  • power-transformer

DISTRIBUTION TRANSFORMERS

Core is made of single phase, Middle Limb/Double Limb wound with two auxiliary limbs.
Helical, Disc, Spiral, coils arrangement are adopted. Copper Foil/Aluminium Foil is used in Low Voltage, High Current Transformer

Amorphous Metal Distribution Transformers (AMDT)

PME Power Solutions (India) Limited has license to manufacture Amorphous Metal Cores & Transformers with technology with Metglas, Inc, USA. It has entered in to a tripartite agreement with PME, Hitachi Metals India & Metglas Inc.

Range upto 500 KVA 33 KV class distribution transformers

Amorphous Metal Transformers Core / Design & Construction

  • distribution-transformer

• Standard ribbon width.
• Use of single grade core material.
A sophisticated process of manufacture & transformer cores, right from automatic cutting line & stacking machine.
• The stack is up righted so that it is resting on edge.
• The under lap end is laced first, then the overlap.
• The outer lap made to match up & protective sheet is closed with tape to prevent joints from opening.
• Core is formed horizontally with respect to the joint window to establish the overlap pattern with the help of hydraulic jacks.
• The arrangement of amorphous core & final shape for use is shown in Picture.

DOWNLOADS BROCHURES


SPECIAL TRANSFORMERS

The special configuration of core/winding is adopted for special application transformers and special care/expertise is required during design/manufacture of transformers.

  • Special-Transformers
Classification of Transformer Range Type
Power Transformer 3.15 MVA to 150 MVA at 330 KV class Core type 3 phase, Generator Transformer, Unit Auxiliary Transformers, Step up and step down Transformers, Interconnecting.

Auto Transformers, Dual Voltage Primary or Secondary Three winding Transformers.
Distribution Transformer 6.3 KVA to 3150 KVA, upto 33 KV classs Core type single phase, Three winding Transformers, Step up and step down Transformers, Dual Voltage Primary or Secondary.
Special Transformers As per customer requirement Auto Transformers, Arc Furnace Transformers, Step up Generator Transformers, Thyristor Duty Transformers, Zig zag Transformers, Voltage Regulators,Earthing Transformer,Rectifier
Transformer,Mining Transformer,Testing Transformer,Transformer for AC/DC Drives.r

Star Rating Distribution Transformers with Energy efficiency level 1, 2 & 3 as per IS 1180:2014 (Part I)

Maximum Ambient Temperature=45°C, Oil temperature Rise: 35°C ,Winding Rise: 40°C,
Tap switch: NIL(For 16 KVA to 100 KVA)Type Of Winding Aluminum wound
Off circuit Tap switch: +5% to -5% @ 2.5%(For 160 & 200 KVA)

2
tab-le

Note:
1- All electrical performances are subject to tolerance as per IS – 2026.
2- Weights & dimension are subject to tolerance of ±10%.
3- LV windings are made using Al. Foil which is excellent in short circuit strength.
4- The dimensions & weights along with complete technical particulars will be furnished on individual query.
5- We supply energy efficient transformers by using Amorphous Core instead CRGO laminations.
6- For 22 kV transformers total loss will be +5% of total losses at 11kV & for 33 kV transformers total loss will be +7.5% of total losses at 11kV.

Star Rating Distribution Transformers with Energy Efficiency Level 1, 2 & 3 as per IS 1180:2014 (Part I)

Maximum Ambient Temperature=45°C, Oil temperature Rise: 35°C ,Winding Rise: 40 ° C,
Type Of Winding : Aluminum wound

1
tab-le

Note:
1- All electrical performances are subject to tolerance as per IS – 2026.
2- Weights &dimension are subject to tolerance of ±10%.
3- LV windings are made using Al. Foil which is excellent in short circuit strength.
4- The dimensions & weights along with complete technical particulars will be furnished on individual query.
5- We supply energy efficient transformers by using Amorphous Core instead CRGO laminations.
6- For 22 kV transformers total loss will be +5% of total losses at 11kV & for 33 kV transformers total loss will be +7.5% of total losses at 11kV.

Star Rating Distribution Transformers with Energy efficiency level 1, 2 & 3 as per IS 1180:2014 (Part I)

Maximum Ambient Temperature=45°C,Oil temperature Rise: 40°C ,Winding Rise: 45°C,
Off circuit Tap switch: +5% to -5% @ 2.5% ,Type Of Winding : Copper wound

3
tab-le

Note:
1-All electrical performances are subject to tolerance as per IS-2026.
2-Weigthts &dimension are subject to tolerance of ±10%.
3- LV windings are made using Cu. Foil which is excellent in short circuit strength.
4- The dimensions & weights along with complete technical particulars will be furnished on individual query.
5- For 22 kV transformers total loss will be +5% of total losses at 11kV.